Self Test Fails - DTX Alien Crosstalk
Fixed in Version 2.04 for your DTX CableAnalyzer. Get the latest code here.
This article is only applicable if you have the DTX Alien Crosstalk Communications modules from the DTX-10GKIT or DTX-AXKIT inserted in your DTX.
For the Self Test to Pass, you must have a good patch cord connected between the two Alien Crosstalk Communications modules in the back of the DTX as well as a good patch cord connected between the two Channel Adapters (DTX-CHA002).
If you only connected between the two Channel Adapters, the Self Test will fail.
This article is only applicable if you have the DTX Alien Crosstalk Communications modules from the DTX-10GKIT or DTX-AXKIT inserted in your DTX.
For the Self Test to Pass, you must have a good patch cord connected between the two Alien Crosstalk Communications modules in the back of the DTX as well as a good patch cord connected between the two Channel Adapters (DTX-CHA002).
If you only connected between the two Channel Adapters, the Self Test will fail.