Launch fiber specifications - OptiFiber Pro

Fluke Networks offers launch cords with reference grade connectors in accordance with standards such as ANSI/TIA-526-14-C and ISO/IEC 14763-3. The requirements of these standards for loss at the connector are 0.10 dB for multimode and  0.20 dB for singlemode.

Our launch cords are made to the following specifications:

Multimode 50/125 µm

  • Cable: Prysmian, MaxCap-OM3
  • Jacket/Trim color: Aqua
  • Insertion Loss (reference grade)1 0.1 dB maximum
  • Return Loss: 40dB 최대
  • Radius of Curvature per GR-326: 7 mm to 25 mm
  • Apex Offset per GR-326: 0 to 50 µm
  • Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
  • Angular Offset per GR-326: -0.3 degrees to +0.3 degrees
  • Fiber Roughness (Rq) per GR-326: 0 to 50 nm
  • Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
  • Length: 105 m ± 3 m

 

Multimode 62.5/125 µm

  • Cable: OFS, Laser Optimized 62.5 XL ±1.0 μm core diameter
  • Jacket/Trim color: Orange
  • Insertion Loss (reference grade)1 0.1 dB maximum 
  • Return Loss: 40dB 최대
  • Radius of Curvature per GR-326: 7 mm to 25 mm
  • Apex Offset per GR-326: 0 to 50 µm
  • Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
  • Angular Offset per GR-326: -0.3 degrees to +0.3 degrees
  • Fiber Roughness (Rq) per GR-326: 0 to 50 nm
  • Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
  • Length: 105 m ± 3 m

 

Singlemode 9/125 µm (UPC)

  • Cable: Corning, SMF 28e+
  • Jacket/Trim color: Yellow
  • Insertion Loss (reference grade)2 0.2 dB maximum
  • Return Loss: 50dB 최대
  • Radius of Curvature per GR-326: 7 mm to 25 mm
  • Apex Offset per GR-326: 0 to 50 µm
  • Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
  • Angular Offset per GR-326: -0.3 degrees to +0.3 degrees
  • Fiber Roughness (Rq) per GR-326: 0 to 50 nm
  • Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
  • Length: 160 m ± 3 m

 

Singlemode 9/125 µm (APC)

  • Cable: Corning, SMF 28e+ (Non bend insensitive)
  • Jacket/Trim color: Yellow/Green
  • Connector color: Green
  • Step or conical endface: Step
  • Insertion Loss (reference grade) 0.15 dB maximum3
  • Return Loss: 65dB 최대
  • Radius of Curvature per GR-326: 5 mm to 12 mm
  • Apex Offset per GR-326: 0 to 50 µm
  • Fiber Height (spherical fit) per GR-326: -100 nm to + 100 nm
  • Angular Offset per GR-326: 7.8 degrees to 8.2 degrees
  • Fiber Roughness (Rq) per GR-326: 0 to 50 nm
  • Ferrule Roughness (Rq) per GR-326: 0 to 50 nm
  • Length: 160 m ± 3 m

 

1Maximum insertion loss for 2.5 mm ferrules is based on interoperability and 2 standard deviations. For maximum insertion loss, 95% should meet the specification. During testing of the insertion loss using a master test cord (MTC), the maximum allowed test is to be less than 0.07 dB to achieve interoperability

2Maximum insertion loss for 2.5 mm ferrules is based on interoperability and 2 standard deviations. For maximum insertion loss, 95% should meet the specification. During testing of the insertion loss using a master test cord, the maximum allowed test should be less than 0.17 dB to achieve interoperability

3Except for E2000 which is 0.40 dB maximum.

 

환경
  • 온도: -20℃ ~ 60℃
  • Relative Humidity (%RH operating without condensation): 95% (10°C to 35°C); 75% (35°C to 40°C) uncontrolled < 10°C
  • 진동: 무작위, 2g 5 - 500 Hz